Doubted for buy this manual as it is my first order here and at not have cover image, I assumed would haven't. However, within 24 hs, already possessed the link to download it. The manual are scanned correctly and have all what is needed. Includes adjustments and diagrams of all circuits. Very satisfied.
;
Really good quality, аll readable.! Wonderful work shop. I recommend to all!
WASH HEATER TROUBLE
MAIN PWB ASSEMBLY
1 2
When checking the voltage between connectors ( 1 , 2 ) during whites washing, Is the voltage 220 - 240V ~ ?
NO
Replace the MAIN PWB ASSEMBLY
220 - 240V~
YES
After power off,is the resistance of wire (RED-YELLOW) connectors between 10 ~30 ?
1 2 3
YELLOW
RED
YES
Normal
NO
After power off and the heater terminal is disconnected, is the resistance 10~30 ?
NO
Replace the HEATER ASSEMBLY
HEATING CONTINUOUSLY ABOVE THE SETTING WATER TEMPERATURE
MAIN PWB ASSEMBLY
2 4 (1)
When disconnect the connector (1) on the, MAIN PWB ASSEMBLY is the resistance of the natural connectors (White), (Blue/White) between 2.5k to 180k (105 ~0 )? 4 3
2 1
Replace the THERMISTOR
NO
(6322FR2046B)
YES
When checking THERMISTOR on the tub is the THERMISTOR loosened above 2mm from the rubber?
YES
Push the THERMISTOR tightly to the rubber.
24
|
|
|
> |
|